The model GF111D high precision DC reference energy meter are used in electric power, metrology, military industry, manufacturing and scientific research institutes and other DC measurement fields or laboratories. Characteristic features of the GF111D are its wide measuring range, high accuracy and high tolerance to unwanted external influences. Its voltage range from 0 to 1200V, current range from 0 to 600A, DC reference standard of accuracy 0.02% or 0.01%. The GF111D DC reference standard offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 8 inch color touch LCD-display. It can automatically test DC energy meter error, energy accumulation , error of time of day. It have been used many by ISO17025 electrical lab in the world.
Electrical parameters | |
---|---|
Accuracy | 0.05%, 0.02%, 0.01% |
Power Supply | One Phase AC 180-265V, or 85-135V, frequency 50/60Hz. |
Power consumption | 20VA |
DC Voltage Measurement | |
Range | 10mV, 100mV, 1V, 10V, 30V, 100V, 300V, 1000V (max 1200V) |
Accuracy | ±(0.012%RD+0.008%RG) |
DC Current Measurement | |
Range | 0.7mA, 3.5mA, 14mA, 35mA, 140mA, 700mA, 1A, 2A, 5A, 10A, 20A, 50A, 100A, 500A (max 600A) |
Accuracy | ±(0.012%RD+0.008%RG) |
DC Power Measurement | |
Power accuracy | ±0.02%, 0.01% |
DC Power Energy Measurement Error | |
power energy | ±0.02%, 0.01% |
Power Pulse Output | |
Power Pulse Output | 20KHz |
Power Pulse Input | |
Energy pulse input | 20KHz |
Function | |
LCD Display | 8 inch 800x600 touch TFT |
Energy accumulation | Yes |
Self-calibration | Yes |
Data storage | Yes |
Pulse input cable | Yes |
Pulse output cable | Yes |
Pulse optical sampler | Optional |
PC software | Optional |
Communication port | USB, RS232, 10/100M LAN |
Standard | |
Standard | IEC 62053-21,22, 23, 41 Ed.1; IEC 60736; ANSI C12.20-2002; JJG-842-2017; JJG596-2012; JJG 1085-2013; JJF 68-2019; DL/T 1478-2015; DL/T 448-2016; GB/T 33708-2017; |
Safety | |
Isolation protection | IEC 61010-1:2001 |
Measurement Category | 300 V CAT III, 600 V CAT II |
Degree of protection | IP40 |
Declaration of conformity | CE & CNAS certified |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 400x440x290 |
Weight (kg) | 12 |
Environmental conditions | |
Ambient temperature | -10°C to +40°C |
Storage temperature | -20°C to +65°C |
Relative humidity | 10%-85% |
Temperature coefficient | ≤0.0005% /℃ |
Influence of external fields | ≤0.05 %/mT |
(1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |