GF6019 DC calibrator/DC power source is suitable for national metrology and testing center, electricity power company and power plants metrology department, electric metrology and testing institutions, also suitable for railway, petroleum, chemical industry and large industrial and mining enterprises, etc.
This GF6019 calibration test equipment can as high accuracy 0.02% DC voltage source and current source, range from 0 to 1050V and 0 to 30A. Its voltage and current channels are independent, high power linear power amplifier, programmable control to output. GF6019 DC power source is a high precision and ideal test equipment in electrical laboratory. This device have been used in global standard ISO17025 laboratory.
Electrical parameters | |
---|---|
Accuracy class | 0.05%, 0.02% |
Power supply | Single phase AC 220V±10% or 110 V±10%, 50/60 Hz |
DC Voltage output | |
Range | 100mV, 300mV, 1V, 3V, 10V, 100V, 300V, 600V, 1000V, (max 1050V) |
Adjustment range | (0-120)% RG |
Adjustment resolution | 0.01% RG, 0.1% RG, 1% RG, 10% RG |
Accuracy | 0.012% RD + 0.008% RG(≥1V); 0.03% RD + 0.02% RG(<1V) |
Stability | 0.005% RG / 1 min(≥1V); 0.01% RG / 1 min(<1V) |
Distortion degree | Better than 0.1% (not capacitive load) |
Load Capacity | Max 25VA |
Ripple contents | ≤1% |
Full load regulation rate | Less than 0.01% RG |
Full load regulation time | Less than 10mS |
Temperature drift | 8 PPM/°C |
Long-term stability | 60 PPM/year |
DC Current output | |
Range | 10uA, 30uA, 100uA, 300uA, 1mA, 3mA, 10 mA, 30mA, 100mA, 300mA, 1A, 3A, 10A, 30A( max 30A) |
Adjustment range | (0-120)% RG |
Adjustment resolution | 0.01% RG, 0.1% RG, 1% RG, 10% RG |
Accuracy | 0.03% RD + 0.02% RG |
Stability | 0.01% RG/1 min |
Distortion degree | Better than 0.1% (not capacitive load) |
Load Capacity | 48VA |
Ripple contents | ≤1% |
Full load regulation rate | Less than 0.01% RG |
Full load regulation time | Less than 10mS |
Temperature drift | 8 PPM/°C |
Long-term stability | 60 PPM/year |
DC Power output | |
Accuracy | 0.05% |
Stability | 0.01% RG / 1 min |
Functions | |
Communication Port | RS232 |
Programmable controlled | Yes |
Key | 19pcs |
LCD | 5.6 inch color display |
Standard | |
Standard | IEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002; JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019; GB/T 33708-2017; JJG 842-2017; DL/T 1112-2017 |
Safety | |
Isolation protection | IEC 61010-1:2001 |
Measurement Category | 300 V CAT III, 600 V CAT II |
Degree of protection | IP20 |
Declaration of conformity | CE & CNAS certified |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 440x360x160 |
Weight (kg) | 12 |
Environmental conditions | |
Operating temperature | 0°C to 50°C |
Storage conditions | -30°C to 60°C |
Relative humidity | ≤85% |