LC-100KV automatic portable oil tester perform accurate breakdown voltage tests on mineral, ester and silicon insulating liquids. Moulded test vessels give repeatable results in the field and laboratory with lock in precision electrode gap setting adjustment wheels. The transparent, shielded lid is a key feature enabling users to see what is happening within the test chamber. It has the functions of overcurrent, overvoltage and short circuit protection.
The LC-100KV transformer oil tester has the advantages of simple operation and beautiful appearance. Due to the full-automatic digital microcomputer control, it has high measurement accuracy, strong anti-interference ability, safety and reliability. It makes evaluating transformers and other dielectric fluid-filled equipment through proper insulated oil testing easier, more accurate, and more economical than ever before.
Electrical parameters | |
---|---|
Power supply | AC 220V±10% or 110V±10%, 50/60Hz AC |
Voltage output | 0-100KV or 0-80KV |
Accuracy | 2% |
Capacity | 1.5KVA |
Voltage step | 0.5kv/s-5.0kv/s |
Power distortion rate | <1% |
Electrode gap | 2.5mm |
Test times | 6 times (1-9 times optional) |
Static release time | 900s (0-9999 s optional) |
Interval rest time | 300s (0-999 s optional) |
Mixing time | 15s (0-999s optional) |
Programmable | Yes |
LCD | 7 inch touch TFT LCD |
Communication | RS232 and USB port |
Volume of the oil cup | 400ml/200ml |
Storage data | 1000sets |
Printer | Internal installed 58mm wide thermal printer. |
Standard | GB/T507-2002 or 1986, DL429.9, IEC60156, ASTM D1816 or D877 |
Mechanical parameters | |
Dimension (L×W×H)(mm) | 410×310×370 |
Weight (kg) | 36 |
Environmental conditions | |
Operating temperature | -10°C to 50°C |
Storage temperature | -40°C to 70°C |
Relative humidity | ≤85%RH |