GF1115B AC EV charger testing equipment can achieve metrological verification, operation and maintenance error verification, start stop and other tests of AC charging piles. It can simultaneously measure the output voltage, current, power, electrical energy, harmonics, phase, frequency, waveform distortion rate and clock error of charging piles. At the same time, it also has functions such as insulation resistance testing, temperature acquisition, humidity acquisition, GPS time calibration, etc. The entire process can be automated and manually tested. Large screen English menu display, with a large amount of information displayed and easy operation. Technically, GF1115 uses various cutting-edge technologies to achieve high performance, such as 24bit high-speed and high-precision synchronous sampling AD and 500M dual core DSP CPU.
Electrical parameters | |
---|---|
Accuracy class | 0.05% |
Power supply | One phase AC 100-265V, frequency 50/60Hz; Li-battery |
Warming-up time | <75VA |
Voltage measurement | |
Range | 380V (0-480.000V) |
Error | ±0.02% (30V-480V) |
Harmonic | 2nd-127nd |
Current Measurement | |
Range | 63A (0-80.000A) |
Error | ±0.02% (1A-80A) |
Harmonic | 2nd-127nd |
Power measurement error | |
Active power | ±0.05% (1A-80A,30-480V) |
Energy measurement error | |
Active energy | ±0.05% (50%-120%Un)/(1%-110%In) |
Phase angle | |
Range | 0°-360.000° |
Resolution | 0.01° |
Error | ±0.05° |
Power factor | |
Range | -1.00000-0-1.00000 |
Resolution | 0.00005 |
Error | 0.00001 |
Frequency | |
Range | 45.0000-65.0000Hz |
Resolution | 0.001 |
Error | ±0.005 |
Pulse output | |
Output channel | 1 |
Energy constant | 1-9999999 |
Pulse ratio | 1:1 |
Output level | 5V |
Output rated frequency | 0-100KHz |
Pulse input | |
Input channel | 1 |
Input level | 3-12V |
Input frequency | 0-100KHz |
Insulation Resistance Measurement | |
Voltage Range | 0-1000V |
Resistance range | 0-50MΩ |
Accuracy | ±5% (1~50MΩ) |
Power Analyzer (AC) | |
AC voltage input (L1\L2\L3\N) | 220V±20% (±0.05%RD) |
AC current input (IL1\IL2\IL3) | 0.1-500A(±0.5%RG) (current sensor optional) |
Accuracy | ±0.5% |
Voltage harmonic times | 2-127 times |
Current harmonic times | 2-127 times |
Wave Recorder Measurement | |
Voltage input range | 0-±1000V |
Accuracy | ±1%RG |
Waveform capture resolution | 10us |
CAN baud rate | 250kbit/s |
Temperature Measurement | |
Range | -40°C to +80°C |
Accuracy | ±0.3°C |
Resolution | 0.1°C |
Humidity Measurement | |
Range | 0%RH-99.99%RH |
Accuracy | ±5%RH |
Resolution | 0.1%RH |
Load | |
Range | 0-9KW |
Min step | 0.01kW/ 200V |
Gear numbers | 8192 |
Function | |
LCD Display | 10 inch 800×600 touch TFT |
Energy accumulation | Yes |
Self-calibration | Yes |
Data storage | Yes |
Auto test | Yes |
Manu test | Yes |
GPS | Yes |
Test report (word file) download | Yes |
PC software | Optional |
Communication port | RS232, USB, WIFI, 10/100M LAN |
Standard | |
Standard | IEC 62053-21, 22, 23; IEC 60736; ANSI C12.20-2002; IEC 62196-2; IEC 62196-3;JJG 597-2005; JJG596-2012; JJG 1085-2013; JJG 1148-2022; GB/T 34657.1-2017; JJF 68-2019; DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016; |
Safety | |
Isolation protection | IEC 61010-1:2001 |
Measurement Category | 300V CAT III, 600V CAT II |
Degree of protection | IP65 |
Declaration of conformity | CE & CNAS certified |
Mechanical parameters | |
Dimension (L×W×H)(mm) | 365×212×532 |
Weight (kg) | 12 |
Environmental conditions | |
Ambient temperature | -20°C to +50°C |
Storage temperature | -30°C to +65°C |
Relative humidity | 10%-85% |
Temperature coefficient | ≤0.005%/°C |
Influence of external fields | ≤0.05%/mT |