GF1115B Ac Ev Charger Testing Equipment With 9kw Load

EV charger testing equipment

GF1115B AC EV charger testing equipment can achieve metrological verification, operation and maintenance error verification, start stop and other tests of AC charging piles. It can simultaneously measure the output voltage, current, power, electrical energy, harmonics, phase, frequency, waveform distortion rate and clock error of charging piles. At the same time, it also has functions such as insulation resistance testing, temperature acquisition, humidity acquisition, GPS time calibration, etc. The entire process can be automated and manually tested. Large screen English menu display, with a large amount of information displayed and easy operation. Technically, GF1115 uses various cutting-edge technologies to achieve high performance, such as 24bit high-speed and high-precision synchronous sampling AD and 500M dual core DSP CPU.

 

Application

  • National Metrology and testing department;
  • Electricity power bureau & power company;
  • Metrological service center;
  • Electrical laboratory;
  • Laboratories of power utilities;
  • EV & Charging pile factory;
  • Third party testing organization;
  • Charging pile operation and maintenance organization;

Features

  • High accuracy class up to 0.05%;
  • High stability, high reliability;
  • Measuring 2nd~127th harmonics;
  • Metal structure, strong and reliable;
  • Waveform display function;
  • Energy accumulating function;
  • Suit for testing EV & Charging AC pile error on site;
  • As a waveform recorder;
  • With 9KW AC load;
  • Meet CCS2 Europe port;
  • With PC software optional;
  • Wide range 0-480V/0-63A;
  • Automatic generation of test report;
  • Portable, small size, drag bar box structure design;
  • Automatic and manual test optional;
  • Using 24bit AD sampling technology;
  • With Li-battery, working more than 8 hours;
  • Built in WIFI, it can be controlled by PDA, PC computer;
  • Safety test, performance test, Compatibility test, Metrological test;
  • Integrated design concept, built-in reference meter, insulation resistance tester, oscilloscope, interface simulator, power analyzer etc;
  • According to JJG 1148-2022 & GB/T 34657.1-2017 standard;

Test Item

  • JJG 1148-2022 Standard;
  • Testing of working error;
  • Testing of clock indication error;
  • Display error verification;
  • Insulation resistance test;
  • Testing of payment amount error;
  • Temperature and humidity detection;
  • GB/T 34657.1-2017 Standard;
  • Connection confirmation test;
  • CP interrupt test;
  • Charging readiness test;
  • CP grounding test;
  • Start up and charging phase test;
  • Continuity loss test of protective grounding conductor;
  • Normal charging end test;
  • Output overcurrent test;
  • Charging connection control sequence test;
  • Disconnect switch S2 test;
  • CC interrupt test;
  • CP loop voltage limit test.
 

Parameters

Electrical parameters
Accuracy class 0.05%
Power supply One phase AC 100-265V, frequency 50/60Hz; Li-battery
Warming-up time <75VA
Voltage measurement
Range 380V (0-480.000V)
Error ±0.02% (30V-480V)
Harmonic 2nd-127nd
Current Measurement
Range 63A (0-80.000A)
Error ±0.02% (1A-80A)
Harmonic 2nd-127nd
Power measurement error
Active power ±0.05% (1A-80A,30-480V)
Energy measurement error
Active energy ±0.05% (50%-120%Un)/(1%-110%In)
Phase angle
Range 0°-360.000°
Resolution 0.01°
Error ±0.05°
Power factor
Range -1.00000-0-1.00000
Resolution 0.00005
Error 0.00001
Frequency
Range 45.0000-65.0000Hz
Resolution 0.001
Error ±0.005
Pulse output
Output channel 1
Energy constant 1-9999999
Pulse ratio 1:1
Output level 5V
Output rated frequency 0-100KHz
Pulse input
Input channel 1
Input level 3-12V
Input frequency 0-100KHz
Insulation Resistance Measurement
Voltage Range 0-1000V
Resistance range 0-50MΩ
Accuracy ±5% (1~50MΩ)
Power Analyzer (AC)
AC voltage input (L1\L2\L3\N) 220V±20% (±0.05%RD)
AC current input (IL1\IL2\IL3) 0.1-500A(±0.5%RG) (current sensor optional)
Accuracy ±0.5%
Voltage harmonic times 2-127 times
Current harmonic times 2-127 times
Wave Recorder Measurement
Voltage input range 0-±1000V
Accuracy ±1%RG
Waveform capture resolution 10us
CAN baud rate 250kbit/s
Temperature Measurement
Range -40°C to +80°C
Accuracy ±0.3°C
Resolution 0.1°C
Humidity Measurement
Range 0%RH-99.99%RH
Accuracy ±5%RH
Resolution 0.1%RH
Load
Range 0-9KW
Min step 0.01kW/ 200V
Gear numbers 8192
Function
LCD Display 10 inch 800×600 touch TFT
Energy accumulation Yes
Self-calibration Yes
Data storage Yes
Auto test Yes
Manu test Yes
GPS Yes
Test report (word file) download Yes
PC software Optional
Communication port RS232, USB, WIFI, 10/100M LAN
Standard
Standard IEC 62053-21, 22, 23; IEC 60736; ANSI C12.20-2002; IEC 62196-2; IEC 62196-3;JJG 597-2005; JJG596-2012; JJG 1085-2013; JJG 1148-2022; GB/T 34657.1-2017; JJF 68-2019; DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016;
Safety
Isolation protection IEC 61010-1:2001
Measurement Category 300V CAT III, 600V CAT II
Degree of protection IP65
Declaration of conformity CE & CNAS certified
Mechanical parameters
Dimension (L×W×H)(mm) 365×212×532
Weight (kg) 12
Environmental conditions
Ambient temperature -20°C to +50°C
Storage temperature -30°C to +65°C
Relative humidity 10%-85%
Temperature coefficient ≤0.005%/°C
Influence of external fields ≤0.05%/mT

Download Catalogue

Related Products