FU2200A Digital Ethernet power meter with data logger

digital ethernet power meter

FU2200A digital ethernet power meter with data logger is a three-phase multifunction power and energy meter manufactured by GFUVE. It provides excellent value for monitoring power and energy management systems. It may be used as data gathering devices for intelligent power distribution or plant automation systems. All monitored data is available via a 10/100M ethernet port and a standard digital RS485 communication port, which is based on the Modbus RTU protocol and TCP/IP protocol.

 

FU2200A ethernet power meter has the PC software and the data logger function, which can set by end users from 1min to 60min intervals to record all kinds of electrical parameter - voltage/current/active power/reactive power/apparent power/kWh/power factor/frequency/phase angle/max/min/harmonics/unballance etc. You can read the data through a PC. Also, you can share the data in the Internet LAN. By the way, it can measure the harmonics from 2nd to 63rd. With a wide range of models to choose from, the FU2200A power meter offers unparalleled value and functionality.

Features

  • 4 quadrant energy;
  • Three years warranty;
  • Power quality analysis;
  • Web browse data function;
  • With load curve function;
  • Unbalance & phase angles;
  • Max/Min log with timestamp;
  • With PC management software;
  • True-RMS measuring parameters;
  • Demands and Multi-tariff energy;
  • Standard panel 96*96 installation;
  • 2MB onboard memory, Extended to 16M;
  • TOU, 4 Tariffs, 6 Seasons, 6 Schedules;
  • High-speed RS485, 10/100M Ethernet port;
  • ANSI and IEC 0.2 or 0.5S accuracy class;
  • Support RTU-Modbus, TCP/IP, SNMP protocol;
  • High precision active energy meter function;
  • Data logging for all electrical parameters;
  • Time interval set from 1minute to 60minutes;
  • Measure individual harmonics from 2nd to 63rd;
 

Applications

  • Power plant;
  • Data logging;
  • Load analysis;
  • Power quality analysis;
  • Power monitoring system;
  • Mobile communication company;
  • Medium and low voltage systems;
  • Electric energy metering cabinet;
  • Low voltage distribution cabinet;
  • High voltage distribution cabinet;
  • Energy consumption monitoring system;
  • Commercial, industrial, power electricity utility;
  • Electric energy metering of photovoltaic power station;
  • Metering of distribution feeders, transformers, generators, capacitor banks and motors;
 

Parameters

Electrical parameters 
Power Supply (AC/DC) AC 85-400V / DC 85-330V
Power consumption: <4VA
Accuracy class 0.5s
Measurement Parameters Voltage (Ph-N); Voltage (Ph-Ph); Current; Frequency; PF; Phase angle; Active power(W); Reactive power(Q); Apparent power(S), 2nd to 63rd harmonics(option)
Harmonics Total harmonics ratio of phase-voltage
Total harmonics ratio of current
2nd to 63rd harmonics ratio of phase-voltage
2nd to 63rd harmonics ratio of current
Maximum Value & Minimum Value Voltage, current, frequency, active power, reactive power, apparent power,demandP,demandQ, demandS.
Computation Forward active power energy
Reverse active power energy
Forward active power energy
Reverse reactive power energy
Measuring Range 0-480V(P-N), 0-800V(P-P), 0-10A, 45-65Hz, -1 ~ 0 ~ 1
Measuring Accuracy Voltage: 0.5%RD±0.05%FS
Current: 0.5%RD±0.05%FS
Active power: 0.5%RD±0.05%FS
Reactive power: 1.5%RD +0.05%FS
Apparent power: 0.5%RD +0.1%FS
Power factor: 0.5%RD
Frequency: 0.05%RD
Active energy: 0.5S, 0.5% , 1%
Maximum Demand Ia, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
Data logger interval time 1minute - 60 minutes can be set
Data logger U1,U2,U3, U12,U23,U31, I1,I2,I3, F, P,Q,S, demand, Ep Eq, Es, Phase,Unbalance,EPrate, EQrate, ESrate
Load recorder or curve Yes
Display Blue back-lit LCD Display
5 display figures
4 operation keys
Communication Support RS-485 interface port, 32 (128) Networking
RTU-ModBus-TCP/IP, SNMP communication protocol
Ethernet 10/100M port (RJ45)
Memory 2M onboard memory,can be extended to 16M.
Data looger interval can set by end users from 1min to 60min.The default is 15min.
You can read the data through a PC, also you can select the data to diaplay and store from software.
Programmable Measuring system: 3P4W/3P3W etc
Transformation Ratio: PT 1-10000; CT 1-10000
Energy Pulse  Provides active & reactive energy pulse output
Pulse parameters can be choosed
Pulse constant range: 0.1-10000kWh/kvarh
Pulse constant can be programmable
Dry contact output (1Ax100V)
Input every voltage/current compsumption 0.5VA/channel
Tariffs 4
Seasons 6
Schedules 6
Connection Mode 3P4W, 3P4W BAL, 3P3W, 3P3W BAL, 1P3W, 1P2W
Clock Yes
Baud 1200-57600, Standard 38400
Web browser Yes
PC management software Yes, downloaddata to excel file
Standard 
Standard IEC 62053-21,22, 23, 24; ANSI C12.20; IEC 62052-11; IEC 62586-2; IEC 61326-1; IEC 61000-4-30: class S; IEEE 519: 2014; EN 50160: 2010; IEC 61557-12; EN61010-2-030:2010; EN61326-1:2013; EN61000-3-2:2014; EN61000-3-3:2013; IEC61557-12; IEC60068-2-1/2/30
Safety 
Isolation protection IEC 61010-1:2001
Measurement Category 300 V CAT III, 600 V CAT II
Degree of protection IP42
Declaration of conformity CE & CNAS certified
Mechanical parameters 
Dimensions (L x W x H) (mm) 96 x 96 x 14
Net Weight 550g
Mounting Panel mounting
Trepanning: 92x92mm
The thickness of installation: 84mm
DIN mounting (optional)
Environmental conditions 
Temperature -5 to +50 °C
Humidity 20%-95%RH, without condensation
Warranty Three years warranty

Index

Parameters Accuracy Resolution Measuring range Show on the display
Voltage 0.2% 0.01V 0-400V 0.5-500kV
Current 0.2% 0.01mA 0-6.5A 1mA-50000A
Active power 0.5% 0.2W 0-2400W/phase -9999MW to +9999MW
Reactive power 2% 0.2var 0-2400var/phase -9999Mvar to +9999Mvar
Apparent power 0.5% 0.2VA 0-2400VA/phase 0-9999MVA
Active demand 0.5% 0.2W 0-2400W/phase -9999MW to +9999MW
Reactive demand 2% 0.2var 0-2400var/phase -9999Mvar to +9999Mvar
Apparent demand 0.5% 0.2VA 0-2400VA/phase 0 to 9999MVA
Apparent demand 0.5% 0.2VA 0-2400VA/phase 0 to 9999MVA
Power factor 0.005 0.0001 -1.000 - 0 - 1.000 -1.000 - 0 - 1.000
Frequency 0.01Hz 0.01Hz 45.000-65.000Hz 45.000-65.000Hz
Active energy 0.5S, 0.5%, 0.2% 0.001kWh 0-999999.999kWh 0-99999999.9kWh
Reactive energy 2% 0.001kvarh 0-999999.999kvarh 0-99999999.9kvarh
Apparent energy 0.5% 0.001VAh 0-999999.999kVAh 0-99999999.9kVAh
Phase angle 0.1° 0.01° 0-359.99° 0-359.99°
Unbalance 2% 0.01% 0-300.00% 0-300.00%
PT ratio 1 1-10000
CT ratio 1 1-10000
Address code 1 1-253
IP Address(default) 192.168.1.16 IP address can be modified