FU2200A digital ethernet power meter with data logger is a three-phase multifunction power and energy meter manufactured by GFUVE. It provides excellent value for monitoring power and energy management systems. It may be used as data gathering devices for intelligent power distribution or plant automation systems. All monitored data is available via a 10/100M ethernet port and a standard digital RS485 communication port, which is based on the Modbus RTU protocol and TCP/IP protocol.
FU2200A ethernet power meter has the PC software and the data logger function, which can set by end users from 1min to 60min intervals to record all kinds of electrical parameter-voltage/current/active power/reactive power/apparent power/kWh/power factor/frequency/phase angle/max/min/harmonics/unballance etc. You can read the data through a PC. Also, you can share the data in the Internet LAN. By the way, it can measure the harmonics from 2nd to 63rd. With a wide range of models to choose from, the FU2200A power meter offers unparalleled value and functionality.
| Electrical parameters | |
|---|---|
| Power Supply (AC/DC) | AC 85-400V/DC 85-330V Power consumption: <4VA |
| Accuracy class | 0.5s |
| Measurement parameters | Voltage (Ph-N); Voltage (Ph-Ph); Current; Frequency; PF; Phase angle; Active power(W); Reactive power(Q); Apparent power(S), 2nd to 63rd harmonics(option) |
| Harmonics | Total harmonics ratio of phase-voltage Total harmonics ratio of current 2nd to 63rd harmonics ratio of phase-voltage 2nd to 63rd harmonics ratio of current |
| Maximum value&minimum value | Voltage, current, frequency, active power, reactive power, apparent power, demandP, demandQ, demandS. |
| Computation | Forward active power energy Reverse active power energy Forward active power energy Reverse reactive power energy |
| Measuring Range | 0-480V (P-N), 0-800V (P-P), 0-10A, 45-65Hz, -1~0~1 |
| Measuring Accuracy | Voltage: 0.5%RD±0.05%FS Current: 0.5%RD±0.05%FS Active power: 0.5%RD±0.05%FS Reactive power: 1.5%RD+0.05%FS Apparent power: 0.5%RD+0.1%FS Power factor: 0.5%RD Frequency: 0.05%RD Active energy: 0.5S, 0.5%, 1% |
| Maximum Demand | Ia, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes |
| Data logger interval time | 1minute-60minutes can be set |
| Data logger | U1, U2, U3, U12, U23, U31, I1, I2, I3, F, P, Q, S, demand, Ep, Eq, Es, Phase, Unbalance, EPrate, EQrate, ESrate |
| Load recorder or curve | Yes |
| Display | Blue back-lit LCD Display 5 display figures 4 operation keys |
| Communication | Support RS-485 interface port, 32 (128) Networking RTU-ModBus-TCP/IP, SNMP communication protocol Ethernet 10/100M port (RJ45) |
| Memory | 2M onboard memory, can be extended to 16M. Data looger interval can set by end users from 1min to 60min.The default is 15min. You can read the data through a PC, also you can select the data to diaplay and store from software. |
| Programmable | Measuring system: 3P4W/3P3W etc Transformation Ratio: PT 1-10000; CT 1-10000 |
| Energy Pulse | Provides active & reactive energy pulse output Pulse parameters can be choosed Pulse constant range: 0.1-10000kWh/kvarh Pulse constant can be programmable Dry contact output (1Ax100V) |
| Input every voltage/current compsumption | 0.5VA/channel |
| Tariffs | 4 |
| Seasons | 6 |
| Schedules | 6 |
| Connection mode | 3P4W, 3P4W BAL, 3P3W, 3P3W BAL, 1P3W, 1P2W |
| Clock | Yes |
| Baud | 1200-57600, standard 38400 |
| Web browser | Yes |
| PC management software | Yes, downloaddata to excel file |
| Standard | |
| Standard | IEC 62053-21,22,23,24; ANSI C12.20; IEC 62052-11; IEC 62586-2; IEC 61326-1; IEC 61000-4-30: class S; IEEE 519: 2014; EN 50160: 2010; IEC 61557-12; EN61010-2-030: 2010; EN61326-1: 2013; EN61000-3-2: 2014; EN61000-3-3: 2013; IEC61557-12; IEC60068-2-1/2/30 |
| Safety | |
| Isolation protection | IEC 61010-1: 2001 |
| Measurement category | 300V CAT III, 600V CAT II |
| Degree of protection | IP42 |
| Declaration of conformity | CE & CNAS certified |
| Mechanical parameters | |
| Dimensions (L×W×H)(mm) | 96×96×14 |
| Net weight | 550g |
| Mounting | Panel mounting Trepanning: 92×92mm The thickness of installation: 84mm DIN mounting (optional) |
| Environmental conditions | |
| Temperature | -5 to +50°C |
| Humidity | 20%-95%RH, without condensation |
| Warranty | Three years warranty |
| Parameters | Accuracy | Resolution | Measuring range | Show on the display |
|---|---|---|---|---|
| Voltage | 0.2% | 0.01V | 0-400V | 0.5-500kV |
| Current | 0.2% | 0.01mA | 0-6.5A | 1mA-50000A |
| Active power | 0.5% | 0.2W | 0-2400W/phase | -9999MW to +9999MW |
| Reactive power | 2% | 0.2var | 0-2400var/phase | -9999Mvar to +9999Mvar |
| Apparent power | 0.5% | 0.2VA | 0-2400VA/phase | 0-9999MVA |
| Active demand | 0.5% | 0.2W | 0-2400W/phase | -9999MW to +9999MW |
| Reactive demand | 2% | 0.2var | 0-2400var/phase | -9999Mvar to +9999Mvar |
| Apparent demand | 0.5% | 0.2VA | 0-2400VA/phase | 0 to 9999MVA |
| Apparent demand | 0.5% | 0.2VA | 0-2400VA/phase | 0 to 9999MVA |
| Power factor | 0.005 | 0.0001 | -1.000-0-1.000 | -1.000-0-1.000 |
| Frequency | 0.01Hz | 0.01Hz | 45.000-65.000Hz | 45.000-65.000Hz |
| Active energy | 0.5S, 0.5%, 0.2% | 0.001kWh | 0-999999.999kWh | 0-99999999.9kWh |
| Reactive energy | 2% | 0.001kvarh | 0-999999.999kvarh | 0-99999999.9kvarh |
| Apparent energy | 0.5% | 0.001VAh | 0-999999.999kVAh | 0-99999999.9kVAh |
| Phase angle | 0.1° | 0.01° | 0-359.99° | 0-359.99° |
| Unbalance | 2% | 0.01% | 0-300.00% | 0-300.00% |
| PT ratio | 1 | 1-10000 | ||
| CT ratio | 1 | 1-10000 | ||
| Address code | 1 | 1-253 | ||
| IP Address(default) | 192.168.1.16 | IP address can be modified |